TM 9-2320-366-20-3
7-75. BATTERY TO 100 AMP REVERSE POLARITY RELAY 24 VDC CABLE
REPLACEMENT (CONT)
(4) Position turbocharger intake hose (8) on intake air
cleaner boot (9) with clamp (10).
(5) Tighten clamp (10) to 36-48 lb-in. (4-5 Nm).
(6) Install terminal lugs TL10 (11) and TL39 (12) on battery
24 vdc cable (13) with nut (14).
c. Follow-On Maintenance.
(1) Connect batteries (para 7-57).
(2) Raise spare tire (TM 9-2320-366-10-2).
(3) Start engine (TM 9-2320-366-10-1).
(4) Check VOLTS gage for 24 vdc (TM 9-2320-366-10-1).
(5) Shut down engine (TM 9-2320-366-10-1).
End of Task.
7-348
|