7-73. 100 AMP ALTERNATOR TO REVERSE POLARITY RELAY 24 VDC CABLE
REPLACEMENT
This task covers:
a. Removal
c. Follow-On Maintenance
b. Installation
INITIAL SETUP
Equipment Conditions
Materials/Parts
Spare tire lowered (TM 9-2320-366-10-2).
Dispenser, Pressure Sensitive Adhesive Tape
Cab raised (TM 9-2320-366-10-1).
(Item 20, Appendix D)
Batteries disconnected (para 7-57).
Ties, Cable, Plastic (Item 69, Appendix D)
Lockwasher (Item 96, Appendix G)
Nut, Self-Locking (Item 143, Appendix G)
Tools and Special Tools
Tool Kit, Genl Mech (Item 46, Appendix C)
Wrench, Torque, 0-175 lb-ft (Item 58, Appendix C)
Wrench, Torque, 0-200 lb-in. (Item 59, Appendix C)
Socket Set, Socket Wrench (Item 34, Appendix C)
a. Removal.
(1) Loosen clamp (1) on turbocharger intake hose (2).
(2) Remove turbocharger intake hose (2) from intake air
cleaner boot (3).
(3) Lift terminal cover (4) on terminal lugs TL1 (5), TL36 (6),
and TL37 (7).
NOTE
Remove plastic cable ties as required.
(4) Remove nut (8), lockwasher (9), and terminal lugs TL1
(5), TL36 (6), and TL37 (7) from reverse polarity relay 24
VDC LOAD terminal (10). Discard lockwasher.