d. Installation.
(1) Install junction box (1) on crane with four washers (2),
lockwashers (3), and screws (4).
(2) Loosen four screws (5) on junction box (1).
(3) Open cover (6) on junction box (1).
(4) Install right side remote control cable (7) in junction box
(1) with four screws (8), lockwashers (9), and nuts (10).
(5) Install quick disconnect terminal (11) on ground strip (12)
position 1.