TM 9-2320-366-20-3
NOTE
Perform steps (4) through (6) on junction
boxes that have not had modification kit
installed.
(4) Unsolder five wires (5) from shutdown relay (6).
WARNING
Wear appropriate eye protection when
removing rivets. Failure to comply may
result in injury to personnel.
(5) Remove three rivets (7) and bracket (8) from junction
box (4).
(6) Remove three nuts (9), lockwashers (10), washers (11),
and shutdown relay (6) from bracket (8). Discard
NOTE
Perform steps (6.1) through (6.3) on junction
boxes that have modification kits installed.
(6.1) Disconnect shutdown relay connector (11.1) from
shutdown relay (11.2).
(6.2) Remove nut (11.3), lockwasher (11.4), washer (11.5),
shutdown relay (11.2) and screw (11.6) from bracket
(11.7). Discard lockwasher.
Change 1
7-166.1/(7-166.2 Blank)
|