(16) Remove four nuts (27), lockwashers (28), screws (29)
and left side remote control cable (30) from junction box
(2). Discard lockwashers.
(17) Remove four quick disconnect terminals (31) from
ground strip (5) positions 16, 17, 18, and 19.
(18) Remove four screws (32) from terminal block (7)
positions 13 through 16.
(19) Remove conduit nut (33) and hoist up solenoid, hoist
down solenoid, boom up solenoid, and boom down
solenoid cable assembly (34) from junction box (2).
Discard conduit nut.