TM 9-2320-366-20-3
7-28. M1089 JUNCTION BOX ASSEMBLY REPLACEMENT/REPAIR (CONT)
(12) Remove two quick disconnect terminals (22) from ground
strip (5) positions 14 and 15.
(13) Remove conduit nut (23), telescope out lockout solenoid
and hoist up lockout solenoid cable assembly (24) from
junction box (2). Discard conduit nut.
(14) Remove quick disconnect terminal (25) from ground strip
(5) position 4.
(15) Remove 12 screws (26) from terminal block (7) positions
7 through 18.
7-162
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |