7-28. M1089 JUNCTION BOX ASSEMBLY REPLACEMENT/REPAIR (CONT)
NOTE
Tag wires and connection points prior to
disconnecting.
(3) Remove quick disconnect terminal (4) from ground strip
(5) position 20.
(4) Remove screw (6) from terminal block (7) position 19.
(5) Remove conduit nut (8) and boom down lockout solenoid
cable (9) from junction box (2). Discard conduit nut.
(6) Remove quick disconnect terminal
(10) from ground
strip (5) position 3.
(7) Remove three screws (11) from terminal block (7)
positions 1, 17, and 19.
|