TM 9-2320-366-20-3
NOTE
Perform steps (6.1) through (6.4) on junction
boxes that have modification kit installed.
(6.1) Disconnect shutdown relay connector (14.1) from
shutdown relay (14.2).
(6.2) Disconnect lockout relay connector (14.3) from lockout
relay (14.4).
(6.3) Remove nut (14.5), lockwasher (14.6), washer (14.7),
shutdown relay (14.2), lockout relay (14.4) and screw
(14.8) from bracket (14.9). Discard lockwasher.
WARNING
Wear appropriate eye protection when
removing rivets. Failure to comply may
result in injury to personnel.
(6.4) Remove two rivets (14.10) and bracket (14.9) from
junction box (4).
Change 1
7-146.1/(7-146.2 Blank)
|