TM 9-2320-366-20-3
NOTE
Tag wires and connection points prior to
disconnecting.
(3) Disconnect quick disconnect terminal (4) from ground
strip (5) position 17.
(4) Remove two screws (6) from terminal block (7) positions
6 and 11.
(5) Remove conduit nut (8) and right jack cylinder proximity
sensor cable (9) from junction box (2). Discard conduit
nut.
(6) Disconnect quick disconnect terminal (10) from ground
strip (5) position 14.
(7) Remove three screws (11) from terminal blocks (7) and
(12) positions 6, 25, and 28.
7-139
|