7-14. ELECTRICAL GAGES REPLACEMENT (CONT)
b. Installation.
CAUTION
Ensure dipswitch settings are correct.
Failure to comply may result in inaccurate
speedometer readings.
NOTE
Perform steps (1) through (3) on
speedometer.
(1)
Remove cover (1) from speedometer (2).
(2) Set dipswitches 3,6,7, and 9 in the down position.
(3) Set dipswitches 1,2,4,5,8, and 10 in the up position.
NOTE
Note position of speedometer prior to
installation.
(4) Position speedometer (2) in instrument panel
assembly (3) with retaining ring (4) and two self
locking nuts (5).
(5) Tighten two self-locking nuts (5) to 9 lb-in. (1 Nm).
(6) Install two protective caps (6) on speedometer (2).
NOTE
Install plastic cable ties as required.
(7) Connect connector PX8 (7) on speedometer
connector (8).
(8) Connect connector clamp (9) on speedometer
connector (8).
c. Follow-On Maintenance.
(1) Install instrument panel assembly (para 7-15).
(2) Check gage(s) operation (TM 9-2320-366-10-1).
End of Task.