TM 9-2320-366-20-3
(18) Install 38 quick disconnect terminals (33) on terminal
board TB1 (26) positions 5, 11, 20, 23, 24, 26, 27, 28,
29, 30, 31, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 46,
47, 50, 51, 52, 53, 54, 56, 57, 58, 59, 60, 61, 62, 63,
and 64.
(19) Position two washers (34) and cover (35) on terminal
board TB1 (26) with two washers (34), lockwashers (36),
and nuts (37).
(20) Position wire 1603 (38) on PDP frame (5) with
lockwasher (39), and screw (40).
(21) Install terminal board TB2 (41) on PDP frame (5) with
two screws (42), lockwashers (43), and nuts (44).
(22) Install 46 quick disconnect terminals (45) on terminal
board TB2 (41) positions 3, 8, 9, 10, 11, 13, 14, 15, 16,
17, 18, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32,
33, 34, 35, 36, 37, 39, 40, 43, 44, 45, 46, 47, 50, 53, 55,
56, 60, 62, 70, 74, 77, and 79.
(23) Position wire 1603 (38) on terminal board TB2 (41) with
washer (46), lockwasher (47), and nut (48).
|