TM 9-2320-366-20-3
(5)
Disconnect voltage regulator connector (10) from
voltage regulator (5).
(6)
Remove two screws (11), lockwashers (12), and
voltage regulator (5) from alternator (13). Discard
lockwashers.
b. Installation.
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area.
If
adhesive, solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(1) Apply sealing compound to threads of two screws (1).
(2) Position voltage regulator (2) on alternator (3) with two
lockwashers (4) and screws (1).
(3) Tighten two screws (1) to 65 lb-in. (7 N m).
(4) Connect voltage regulator connector (5) to voltage
regulator (2).
7-21
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |