TM 9-2320-366-20-3
7-2. 100 AMP ALTERNATOR REPLACEMENT (CONT)
(24) Remove self-locking nut (32), washer (33), and two
washers (34) from alternator (3).
(25) Position two washers (34), terminal lug TL60 (35),
washer (33), and self-locking nut (32) on alternator (3).
(26) Tighten self-locking nut (32) to 80 lb-in. (9 N m).
(27) Position dust boot (36) on terminal lug TL60 (35).
(28) Remove screw (37), lockwasher (38), and washer (39)
from alternator (3).
(29) Position ground strap (40), washer (39), and terminal lug
TL5 (41) on alternator (3) with lockwasher (38) and
screw (37).
(30) Tighten screw (37) to 80 lb-in. (9 N m).
c. Follow-On Maintenance.
(1) Install alternator belts (para 7-3).
(2) Connect batteries (para 7-57).
(3) Start engine (TM 9-2320-366-10-1).
(4) Check alternator operation (TM 9-2320-366-10-1).
(5) Shut down engine (TM 9-2320-366-10-1).
End of Task.
Change 1
|