TM 9-2320-366-20-3
6-8. PERSONNEL HEATER HOSES REPLACEMENT (CONT)
(11) Lower cab (TM 9-2320-366-10-1).
NOTE
Heater outlet hose is marked with an
arrow pointing down.
(12) Position heater outlet hose (6) on return fitting (10).
NOTE
Heater inlet hose is marked with an arrow
pointing up.
(13) Position heater inlet hose (7) on supply fitting (11).
(14) Engage as many clamp tabs (4) as possible in tab
windows (5) allowing little or no play between
clamps (2) and heater outlet hose (6) and heater
inlet hose (7).
(15) Tighten two clamps (2) to 8-9 lb-in. (1 Nm).
(16) Raise cab (TM 9-2320-366-10-1).
NOTE
Minimum allowable gap on clamp is 0.1 in.
(0.3 cm). If gap is less than 0.1 in. (0.3
cm), remove and re-install clamp
(17) Measure gap on two clamps (2).