TM 9-2320-366-20-3
This task covers:
a.
Ether Cylinder Removal
e. Ether Valve Removal
b.
Ether Cylinder Installation
f . Ether Valve Installation
c.
Clamp Removal
g. Follow-On Maintenance
d.
Clamp Installation
INITIAL SETUP
Equipment Conditions
Materials/Parts
Batteries disconnected (para 7-57).
Gasket (Item 26, Appendix G)
Spare tire lowered (TM 9-2320-366-10-2).
Nut, Self-Locking (4) (Item 153, Appendix G)
Tools and Special Tools
Goggles, Industrial (Item 15, Appendix C)
Tool Kit, Genl Mech (Item 46, Appendix C)
Wrench, Torque, 0-175 lb-ft (Item 58, Appendix C)
WARNING
Starting fluid is toxic and highly flamma-
ble. Container is pressurized. NEVER
heat container and NEVER discharge
starting fluid in confined areas or near
open flame. Failure to comply may cause
serious injury or death to personnel.
a. Ether Cylinder Removal.
(1) Remove wingnut (1) from clamp (2).
(2) Remove ether cylinder (3) and gasket (4) from ether
valve (5). Discard gasket.
(3) Remove ether cylinder (3) from clamp (2).
(4) Remove cap (6) from cap retainer (7).
(5) Install cap (6) on ether valve (5).
Change 1
|