TM 9-2320-366-20-3
aa5. M1089 LH OR RH 30K WINCH CABLE DRUM TENSIONER DOES NOT OPERATE (CONT)
WARNING
Read WARNING
KNOWN INFO
TEST OPTIONS
on following page.
3.
Main winch LH/RH freespools.
Air Pressure Test
Is 75-120 PSI
STE/ICE-R Test #50
POSSIBLE PROBLEMS
(518-827 kPa) present at
REASON FOR QUESTION
pneumatic manifold (refer to
Faulty 30K winch pneumatic
Table 2-65.2. 30K Winch
manifold solenoid L8/L4.
If 75-120 PSI (518-827 kPa) is
Pneumatic Manifold Drum
Faulty M1089 LH/RH 30K
not present, 30K winch
Tensioner Solenoids) port 1?
winch pneumatic valve
pneumatic manifold solenoid
assembly.
L8/L4 is faulty.
Faulty air hose.
NO
Repair M1089 30K winch pneumatic
manifold solenoid or replace solenoid (refer to
YES
Drum Tensioner Solenoids) (para 17-29).
2-2430.4
Change 1
|