|
|
TM 9-2320-366-20-3
WARNING
Wear protective goggles to protect against
possible injury from release of high pressure
air. Failure to comply may result in injury to
personnel.
NOTE
Tag air hose and connection point prior to
disconnecting
AIR PRESSURE TEST STE/ICE-R TEST #50
(1) Open LH and RH catwalks.
(2) Disconnect input air hose from input tee
fitting on pressure regulator.
(3) Connect input air hose to M1089 30K
winch pneumatic test adapter.
(4) Install STE/ICE-R 0-1000 PSI transducer on
M1089 30K winch pneumatic test adapter.
(5) Start engine (TM 9-2320-366-10-1).
(6) Perform STE/ICE-R Test #50 and note
reading on STE/ICE-R.
(7) If 75-120 PSI (518-827 kPa) is not present,
go to step 5 of this fault.
(8) Shut down engine (TM 9-2320-366-10-1).
(9) Drain air tanks (TM 9-2320-366-10-1).
(10) Disconnect input air hose from M1089 30K
winch pneumatic test adapter.
Change 1
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |