TM 9-2320-366-20-3
WARNING
Wear protective goggles to protect against
possible injury from release of high pressure
air. Failure to comply may result in injury to
personnel.
NOTE
Tag air hose and connection piont prior to
disconnecting
AIR PRESSURE TEST STE/ICE-R TEST #50
(1) Disconnect air hose from RH 30K winch
freespool input 90 degree fitting.
(2) Install tube nipple on M1089 30K winch
pnematic test adapter.
(3) Connect air hose to M1089 30K winch
pneumatic test adapter.
(4) Start engine (TM 9-2320-366-10-1) and
allow vehicle to build air pressure.
(5) Position MAIN WINCH RH FREESPOOL
switch to ON.
(6) Perform STE/ICE-R Test #50 and note
reading on STE/ICE-R.
(7) If 75-120 PSI (518-827 kPa) is not present,
replace air hose (para 23-5).
(8) If 75-120 PSI (518-827 kPa) is present,
notify DS Maintenance, RH 30K winch
assembly is faulty.
(9) Shutdown engine (TM 9-2320-366-10-1).
(10) Drain air tanks (TM 9-2320-366-10-1).
(11) Positon MAIN WINCH RH FREESPOOL
switch to OFF.
(12) Remove STE/ICE-R 0-1000 PSI transducer
from M1089 30K winch pneumatic test
adapter.
(13) Disconnect air hose from M1089 30K
winch pneumatic test adapter.
(14) Connect air hose to RH 30K winch free
spool 90 degree fitting.
Change 1
|