Click here to make tpub.com your Home Page

Page Title: AIR PRESSURE TEST
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-366-20-3
WARNING
Wear protective goggles to protect against
possible injury from releases of high pressure
air. Failure to comply may result in injury to
personnel.
AIR PRESSURE TEST
NOTE
LH and RH air hose are removed the same
way. LH hose shown.
(1) Disconnect air hose from LH/RH 30K winch
freespool input 90 degree fitting.
(2) Start engine (TM 9-2320-366-10-1).
(3) If air pressure is not present at air hose,
perform Wrecker Hydraulic System
Troubleshooting task w4. M1089 LH 30K
Winch Does Not Operate or w9. M1089 RH
30K Winch Does Not Operate.
(4) If air pressure is present at air hose, replace
30K winch pneumatic manifold solenoid
valve (refer to Table 65.1. 30K Winch
Freespool Solenoid Valves) (para 17-29).
(5) Shut down engine (TM 9-2320-366-10-1).
(6) Connect air hose to LH/RH 30K winch free
spool input 90 degree fitting.
Table 65.1. 30K Winch Freespool Solenoid Valves
30K Winch
LH
L19
RH
L17
Change 1