TM 9-2320-366-20-3
WARNING
Wear protective goggles to protect against
possible injury from releases of high pressure
personnel.
AIR PRESSURE TEST
NOTE
LH and RH air hose are removed the same
way. LH hose shown.
(1) Disconnect air hose from LH/RH 30K winch
freespool input 90 degree fitting.
(2) Start engine (TM 9-2320-366-10-1).
(3) If air pressure is not present at air hose,
perform Wrecker Hydraulic System
Troubleshooting task w4. M1089 LH 30K
Winch Does Not Operate or w9. M1089 RH
30K Winch Does Not Operate.
(4) If air pressure is present at air hose, replace
30K winch pneumatic manifold solenoid
valve (refer to Table 65.1. 30K Winch
Freespool Solenoid Valves) (para 17-29).
(5) Shut down engine (TM 9-2320-366-10-1).
(6) Connect air hose to LH/RH 30K winch free
spool input 90 degree fitting.
30K Winch
LH
L19
RH
L17
Change 1
|