TM 9-2320-366-20-3
Cont. from page 2-2416.7.
WARNING
Drop hydraulic pressure to zero before
disconnecting any hydraulic hoses. Failure
to comply may result in injury to
personnel.
Hydraulic fluid (MIL-H-5606) is TOXIC.
Wear protective goggles and gloves; use
only in well ventilated area; avoid contact
with skin, eyes, and clothes. Skin and
clothing that come into contact with
hydraulic fluid should be washed
immediately. Saturated clothing should be
removed immediately. Failure to comply
may result in injury to personnel.
Compressed air used for cleaning purposes
will not exceed 30 psi (270 kPa). Use
only with effective chip guarding and
personal protective equipment (goggles,
shields, gloves, etc.). Failure to comply
may result in injury to personnel.
NOTE
Perform steps (13) through (25) on
hydraulic manifolds installed on vehicles
S/N 7559 and higher or on vehicles where
hydraulic manifolds have two valves on
left side.
(13) Remove pin from hydraulic manifold cover
and lower cover.
(14) Cycle FUNCTION SELECT knob through all
settings.
(15) Cycle SPARE TIRE knob through both
selector settings.
(16) Remove nut, knob, spring, spacer,
retainer ring, and rubber sleeve from
SPARE TIRE valve.
(17) Remove SPARE TIRE valve from hydraulic
manifold.
(18) Remove orifice filter from hydraulic manifold.
(19) If debris is present in orifice filter, replace
orifice filter.
(20) Remove orifice screw from hydraulic
manifold.
(21) If debris is present in orifice screw, clean
orifice screw with compressed air.
(22) Install orifice screw and orifice filter in
hydraulic manifold.
(23) Install SPARE TIRE valve in hydraulic
manifold.
(24) Install rubber sleeve, retainer ring,
spacer, spring, knob, and nut on
hydraulic manifold.
(25) Close hydraulic manifold cover and
install pin.
Change 1
|