TM 9-2320-366-20-3
TM
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector J31-9.
(3)
Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4)
If continuity is not present, repair wire 3028
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
CONTINUITY TEST
(1)
Remove screw and terminal lug TL178
from audible alarm.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter to
connector J31-17.
(4)
Connect negative (-) probe of multimeter to
terminal lug TL178 and note reading on
multimeter.
(5)
If continuity is not present, repair wire 32
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
(6)
If continuity is present, replace audible
alarm (para 7-43).
(7)
Install terminal lug TL178 on audible
alarm with screw.
(8)
Connect connector P31 to connector J31.
(9)
Install instrument panel assembly (para 7-15).
2-2381
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |