x18. TROOP TRANSPORT ALARM DOES NOT OPERATE
INITIAL SETUP
Tools and Special Tools
Equipment Conditions
Tool Kit, Genl Mech (Item 46, Appendix C)
Engine shut down (TM 9-2320-366-10-1).
STE/ICE-R (Item 41, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
Personnel Required
Wrench, Torque, 0-200 lb-in. (Item 59, Appendix C)
(2)
Wire, Elect, 50 ft (Item 71, Appendix D)
References
TM 9-4910-571-12&P
START
KNOWN INFO
TEST OPTIONS
1.
Continuity Test or
Nothing.
STE/ICE-R Test #91
Is continuity present across
POSSIBLE PROBLEMS
REASON FOR QUESTION
troop transport alarm
switch?
Faulty troop transport alarm
If continuity is not present,
switch.
troop transport alarm switch is
Faulty troop transport alarm
faulty.
cable assembly.
Faulty troop transport alarm
switch connector.
Faulty engine control cable
assembly.
NO
Faulty dashboard cable
assembly.
Faulty audible alarm.
Replace troop transport
YES
alarm switch (para 20-70).
Change 1