TM 9-2320-366-20-3
BATTLE COMMAND BRIGADE OR BELOW (FBCB)
INITIAL SETUP
Equipment Conditions
Tools/Special Tools
Engine shut down (TM 9-2320-366-10-2)
Multimeter, Digital (Item 22, Appendix C)
Tool Kit, Genl Mech (Item 46, Appendix C)
Materials/Parts
Ties, Cable, Plastic (Item 69, Appendix D)
Personnel Required
(2)
START
WARNING
Read WARNING
TEST OPTIONS
TEST OPTIONS
on following page.
1.
Voltage Test or
Circuit breaker CB8 is not
STE/ICE-R Test #89
tripped.
Is 24 VDC present at
REASON FOR QUESTION
terminal lug TL2?
POSSIBLE PROBLEMS
If 24 VDC is not present, go to
step 2 of this fault. If 24 VDC
Faulty circuit breaker CB8.
is present, perform SINCGARS/
Faulty digitization rack power
FBCB troubleshooting.
supply.
Faulty SINCGARS/FBCB.
NO
YES
Go to step 2 of this fault.
Contact supervisor, SINCGARS/FBCB
troubleshooting needs to be performed.
Change 2
|