TM 9-2320-366-20-3
INITIAL SETUP
Equipment Conditions
Tools/Special Tools
Engine shut down (TM 9-2320-366-10-2)
Multimeter, Digital (Item 22, Appendix C)
Tool Kit, Genl Mech (Item 46, Appendix C)
Materials/Parts
Ties, Cable, Plastic (Item 69, Appendix D)
Personnel Required
(2)
START
WARNING
Read WARNING
TEST OPTIONS
TEST OPTIONS
on following page.
1.
Voltage Test or
Circuit breaker CB6 is not
STE/ICE-R Test #89
tripped.
Is 24 VDC present at terminal
REASON FOR QUESTION
lug TL3?
POSSIBLE PROBLEMS
If 24 VDC is not present, go to
step 2 of this fault. If 24 VDC
Faulty circuit breaker CB6.
is present, perform Driver
Faulty digitization rack power
Visual Enhancement (DVE)
supply.
troubleshooting.
Faulty Driver Visual
Enhancement (DVE) system.
NO
YES
Go to step 2 of this fault.
Contact supervisor, Driver Visual
Enhancement (DVE) troubleshooting
needs to be performed.