TM 9-2320-366-20-3
x2. NO POWER TO MOBILE TRACKING SYSTEM (MTS) SENSE (CONT)
WARNING
Read WARNING
TEST OPTIONS
TEST OPTIONS
on following page.
3.
Voltage Test or
Circuit breaker CB1 is not
STE/ICE-R Test #89
tripped.
Is 24 VDC present at
REASON FOR QUESTION
Circuit breaker CB1 OK.
terminal lug TL15?
If 24 VDC is not present,
POSSIBLE PROBLEMS
power cable from terminal lug
TL15 to terminal lug TL22 is
Faulty power cable from
faulty. If 24 VDC is present,
terminal
Power Distribution Panel (PD2)
lug TL15 to terminal lug TL22.
is faulty.
Faulty Power Distribution
Panel (PD2).
NO
Replace power cable from terminal lug
YES
TL15 to terminal lug TL22 (para 20-81).
Replace Power Distribution Panel
(PD2) (para 20-81).
2-2286
Change 2
|