TM 9-2320-366-20-3
INITIAL SETUP
Equipment Conditions
Tools/Special Tools
Engine shut down (TM 9-2320-366-10-2)
Multimeter, Digital (Item 22, Appendix C)
Tool Kit, Genl Mech (Item 46, Appendix C)
Materials/Parts
Ties, Cable, Plastic (Item 69, Appendix D)
Personnel Required
(2)
START
WARNING
Read WARNING
TEST OPTIONS
TEST OPTIONS
on following page.
1.
Voltage Test or
Nothing.
STE/ICE-R Test #89
Is 24 VDC present at
POSSIBLE PROBLEMS
REASON FOR QUESTION
terminal lug TL16?
This question eliminates
Circuit breaker CB11 tripped.
possible problems and
Faulty circuit breaker CB11.
determines where
Faulty power cable from
troubleshooting continues.
terminal lug TL24 to terminal
lug TL20.
Faulty power cable from
terminal lug TL23 to terminal
NO
lug TL16.
Faulty power cable from
terminal lug TL18 to terminal
block TB2.
YES
Go to step 2 of this fault.
Faulty Power Distribution
Panel (PD1).
Go to step 5 of this fault.
Change 2
|