Click here to make tpub.com your Home Page

Page Title: NO POWER TO DIGITIZATION RACK
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-366-20-3
x1. NO POWER TO DIGITIZATION RACK
INITIAL SETUP
Equipment Conditions
Tools/Special Tools
Engine shut down (TM 9-2320-366-10-2)
Multimeter, Digital (Item 22, Appendix C)
Tool Kit, Genl Mech (Item 46, Appendix C)
Materials/Parts
Ties, Cable, Plastic (Item 69, Appendix D)
Personnel Required
(2)
START
WARNING
Read WARNING
TEST OPTIONS
TEST OPTIONS
on following page.
1.
Voltage Test or
Nothing.
STE/ICE-R Test #89
Is 24 VDC present at
POSSIBLE PROBLEMS
REASON FOR QUESTION
terminal lug TL16?
This question eliminates
Circuit breaker CB11 tripped.
possible problems and
Faulty circuit breaker CB11.
determines where
Faulty power cable from
troubleshooting continues.
terminal lug TL24 to terminal
lug TL20.
Faulty power cable from
terminal lug TL23 to terminal
NO
lug TL16.
Faulty power cable from
terminal lug TL18 to terminal
block TB2.
YES
Go to step 2 of this fault.
Faulty Power Distribution
Panel (PD1).
Go to step 5 of this fault.