w10. M1089 MATERIAL HANDLING CRANE (MHC) HAND PUMP DOES NOT WORK
INITIAL SETUP
Equipment Conditions
Tools and Special Tools
Engine shut down (TM 9-2320-366-10-1).
Tool Kit, Genl Mech (Item 46, Appendix C)
Pan, Drain (Item 24, Appendix C)
Goggles, Industrial (Item 15, Appendix C)
Materials/Parts
Rag, Wiping (Item 50, Appendix D)
START
WARNING
KNOWN INFO
TEST OPTIONS
Read WARNING
1.
Hydraulic oil level OK.
Hand Pump Test
on following page.
REASON FOR QUESTION
Hydraulic lines
and fittings OK.
Faulty check valve or hand
Does hand pump
All functions operate
pump will prevent manual
build pressure?
with PTO engaged.
operation of crane.
POSSIBLE PROBLEMS
Faulty input check valve.
Faulty hand pump.
NO
YES
Notify DS Maintenance.
Notify DS Maintenance.