TM 9-2320-366-20-3
TM
REMOTE CONTROL TEST
(1)
Connect remote control unit to RH remote
control connector (J2) at rear of wrecker
(TM 9-2320-366-10-1).
(2)
Start engine (TM 9-2320-366-10-1).
(3)
Position PTO switch to on (TM
9-2320-366-10-1).
(4)
Position STATION SELECTOR switch to
REMOTE CONTROL (TM 9-2320-366-10-1).
(5)
Check if folding cylinder operates (UP or
DOWN) at REMOTE CONTROL panel
(TM 9-2320-366-10-1).
(6)
Position STATION SELECTOR switch to
WRECKER CONTROL panel
(TM 9-2320-366-10-1).
(7)
Check if folding cylinder operates (UP or
DOWN) from wrecker control panel.
(8)
If folding cylinder does not operate from
remote or wrecker control panels, notify DS
Maintenance.
(9)
If folding cylinder operates from wrecker
control panel but not from remote, perform
Electrical System Troubleshooting (e137. All
Wrecker Functions Do Not Operate
From Wrecker Remote Control).
(10)
Position PTO switch to off (TM
9-2320-366-10-1).
(11)
Shut down engine (TM 9-2320-366-10-1).
(12)
Disconnect remote control unit and stow.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |