TM 9-2320-366-20-3
TM
INITIAL SETUP
Equipment Conditions
Tools and Special Tools
Engine shut down (TM 9-2320-366-10-1).
Tool Kit, Genl Mech (Item 46, Appendix C)
START
KNOWN INFO
TEST OPTIONS
1.
Visual inspection
PTO OK.
REASON FOR QUESTION
Left 30K winch OK.
Are hydraulic tubes
Oil quantity may be
Right 30K winch OK.
and fittings to MHC
insufficient to operate
Stifflegs OK.
free from leaks and
MHC if hydraulic hoses
15K self-recovery
damage?
are leaking or damaged.
winch OK.
Underlift OK.
POSSIBLE PROBLEMS
NO
Damaged hydraulic tube(s)
or fitting(s).
Faulty electrical system.
Replace damaged oil
YES
tube(s) and fitting(s)
(para 17-15).
Perform Electrical System
Troubleshooting (e120. M1089
Material Handling Crane (MHC)
Does Not Operate).
|