TM 9-2320-366-20-3
u2. SUSPENSION DOES NOT COMPRESS AND/OR RETURN TO NORMAL (CONT)
KNOWN INFO
TEST OPTIONS
6.
Pressure Test or
Other hydraulic manifold
STE/ICE-R Test #51
functions OK.
Is 2,500-4,000 psi
REASON FOR QUESTION
Hydraulic hoses free from
(17,238-27,580 kPa)
leaks.
present at suspension
If 2,500-4,000 psi (17,238-
Hydraulic hoses 508 and 510
release tee fitting
27,580 kPa) is present,
OK.
output port?
hydraulic hose 513 is faulty.
Suspension compression tee
fitting OK.
Air/hydraulic manifold OK.
Hydraulic hose 512 OK.
POSSIBLE PROBLEMS
Faulty hydraulic hose 513.
Faulty suspension release tee
NO
fitting.
Faulty suspension cylinder(s).
Faulty hydraulic hose(s) 509
and/or 511.
Go to step 7
YES
of this fault.
Replace hydraulic
hose 513 (para 19-12).