TM 9-2320-366-20-3
PRESSURE TEST
(1) Position drain pan under air/hydraulic
manifold
(2) Disconnect hydraulic hose 512 from
SUSP COMPRESS port.
(3) Connect STE/ICE-R between hydraulic
hose 512 and SUSP COMPRESS port.
(4) Start engine (TM 9-2320-366-10-1).
(5) Position SUSPENSION knob to RAISE
(TM 9-2320-366-10-1).
(6) Position FUNCTION SELECT knob
to SUSPENSION (TM 9-2320-366-10-1).
(7) Push and hold PUMP plunger button
(TM 9-2320-366-10-1) and perform
STE/ICE-R Test #51.
(8) If 2,500-4,000 psi (17,238-27,580 kPa) is
not present, repair or replace air/hydraulic
manifold (para 19-4).
(9) If 2,500-4,000 psi (17,238-27,580 kPa) is
present, replace hydraulic hose 512
(para 19-12).
(10) Disconnect STE/ICE-R from hydraulic hose
512 and SUSP COMPRESS port.
(11) Connect hydraulic hose 512 to SUSP
COMPRESS port.
Change 1
2-2230.9
|