TM 9-2320-366-20-3
PRESSURE TEST
(1) Disconnect hydraulic hose 512 from
suspension compression tee fitting input
port.
(2) Connect STE/ICE-R between hydraulic
hose 512 and suspension compression
tee fitting input port.
(3) Start engine (TM 9-2320-366-10-1).
(4) Position SUSPENSION knob to RAISE
(TM 9-2320-366-10-1).
(5) Position FUNCTION SELECT knob
to SUSPENSION (TM 9-2320-366-10-1).
(6) Push and hold PUMP plunger button
(TM 9-2320-366-10-1) and perform
STE/ICE-R Test #51.
(7) If 2,500-4,000 psi (17,238-27,580 kPa) is
not present, go to step 5 of this fault.
(8) If 2,500-4,000 psi (17,238-27,580 kPa) is
present, replace suspension
compression tee fitting (para 19-12).
(9) Disconnect STE/ICE-R from hydraulic hose
512 and suspension compression tee
fitting input port.
(10) Connect hydraulic hose 512 to suspension
compression tee fitting input port.