TM 9-2320-366-20-3
u2. SUSPENSION DOES NOT COMPRESS AND/OR RETURN TO NORMAL (CONT)
KNOWN INFO
TEST OPTIONS
4.
Pressure Test or
Other hydraulic manifold
STE/ICE-R Test #51
functions OK.
Is 2,500-4,000 psi
REASON FOR QUESTION
Hydraulic hoses free from
(17,238-27,580 kPa)
leaks.
present at suspension
If 2,500-4,000 psi (17,238-
Hydraulic hoses 508 and 510
compression tee fitting
27,580 kPa) is present,
OK.
input port?
suspension compression tee
Hydraulic hose 513 OK.
fitting is faulty.
Suspension release tee fitting
OK.
Suspension cylinders OK.
Hydraulic hoses 509 and 511
OK.
POSSIBLE PROBLEMS
NO
Faulty suspension compression
tee fitting.
Faulty air/hydraulic manifold.
Faulty hydraulic hose 512.
Go to step 5
YES
of this fault.
Replace suspension
compression tee fitting
(para 19-12).
2-2230.6
Change 1
|