TM 9-2320-366-20-3
WARNING
Drop hydraulic pressure to zero before
disconnecting any hydraulic hoses. Failure
to comply may result in injury to
personnel.
Hydraulic oil (MIL-H 5605) is TOXIC.
Wear protective goggles and gloves. Use
only in well ventilated area. Avoid
contract with skin, eyes, and clothes.
Skin and clothing that come into contact
with hydraulic oil should be washed
immediately. Failure to comply may
result in injury to personnel.
NOTE
SYSTEM PARK control must be engaged
(TM 9-2320-366-10-1) before operating
SUSPENSION compression.
PRESSURE TEST
(1) Position drain pan under RH suspension
cylinder.
(2) Disconnect hydraulic hose 508 from RH
suspension cylinder input port.
(3) Connect STE/ICE-R between hydraulic
hose 508 and RH suspension cylinder
input port.
(4) Start engine (TM 9-2320-366-10-1).
(5) Position FUNCTION SELECT knob to
SUSPENSION (TM 9-2320-366-10-1).
(6) Push and hold PUMP plunger button
(TM 9-2320-366-10-1) and perform
STE/ICE-R Test #51.
(7) Shut down engine (TM 9-2320-366-10-1).
(8) Disconnect STE/ICE-R from RH suspension
cylinder input port and hydraulic hose 508.
(9) Connect hydraulic hose 508 to RH
suspension cylinder input port.
(10) Repeat steps (1) through (9) on LH
suspension cylinder and hydraulic hose
510.
(11) If 2,500-4,000 psi (17,238-27,580 kPa) is
not present at either suspension cylinder,
go to step 3 of this fault.
Change 1
|