PRESSURE TEST
(1) Position drain pan under air/hydraulic
manifold.
(2) Disconnect hydraulic hose 520 from
port T2.
(3) Connect STE/ICE-R between hydraulic
hose 520 and port T2.
(4) Start engine (TM 9-2320-366-10-1).
(5) Position SUSPENSION knob to LOWER
(TM 9-2320-366-10-1).
(6) Position FUNCTION SELECT knob to
SUSPENSION (TM 9-2320-366-10-1).
(7) Push and hold PUMP plunger button
(TM 9-2320-366-10-1) and perform
STE/ICE-R Test #51.
(8) If 2,500-4,000 psi (17,238-27,580 kPa) is
not present, replace air/hydraulic manifold
(para 19-4).
(9) If 2,500-4,000 psi (17,238-27,580 kPa) is
present, replace hydraulic hose 520
(para 19-12).
(10) Disconnect STE/ICE-R from hydraulic hose
520 and port T2.
(11) Connect hydraulic hose 520 to port T2.