TM 9-2320-366-20-3
INITIAL SETUP
Equipment Condition
Tools and Special Tools
Engine shut down (TM 9-2320-366-10-1).
Tool Kit, Genl Mech (Item 46, Appendix C)
STE/ICE-R (Item 41, Appendix C)
Personnel Required
Pan, Drain (Item 24, Appendix C)
(2)
Goggles, Industrial (Item 15, Appendix C)
Transducer, 10,000 PSI (Item 1, Appendix J)
Material/Parts
Gloves, Rubber (Item 13, Appendix C)
Filter Assembly (2) (Item 14, Appendix G)
Rag, Wiping (Item 50, Appendix D)
References
TM 9-4910-571-12&P
START
KNOWN INFO
TEST OPTIONS
1.
Visual Inspection
Hydraulic hoses free from
REASON FOR QUESTION
leaks.
Does either PUMP button or
This question eliminates
back-up hydraulic pump
POSSIBLE PROBLEMS
possible problems and
operate?
determines where
Faulty air/hydraulic manifold
troubleshooting continues.
filter(s).
Faulty hydraulic hose 515.
Faulty air/hydraulic power unit.
Faulty air hose 507.
Faulty secondary air tank
inversion valve.
NO
Faulty air hose 502.
Faulty hydraulic hose 514.
Faulty back-up hydraulic pump.
Faulty hydraulic hose 521.
Faulty hydraulic hose 520.
Faulty air/hydraulic manifold.
Go to step 10
YES
of this fault.
Change 1
|