(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector PX7-9.
(3)
Connect negative (-) probe of multimeter to
connector J111D and note reading on multimeter.
(4)
If continuity is not present, repair wire 1528
(para 2-45) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
(5)
Connect lighted indicator display to connector
PX7.
(6)
Position lighted indicator display in instrument
panel assembly with four screws.
(7)
Tighten four screws to 6-10 lb-in. (1 Nm).