TM 9-2320-366-20-3
FAILS TO INFLATE OR DEFLATE
INITIAL SETUP
Equipment Conditions
Tools and Special Tools
Engine shut down (TM 9-2320-366-10-1).
Tool Kit, Genl Mech (Item 46, Appendix C)
Pan, Wash (Item 25, Appendix C)
Materials/Parts
Goggles, Industrial (Item 15, Appendix C)
Soap, Laundry (Item 63, Appendix D)
START
WARNING
Read WARNING
KNOWN INFO
TEST OPTIONS
on following page.
1.
Visual Inspection
Front and rear air
gages read 120 psi.
REASON FOR QUESTION
Is CTIS air hoses and
POSSIBLE PROBLEMS
fittings free from air leaks
If air is leaking during inflation
Leaking air hoses or fittings.
during inflation mode?
mode, CTIS air hose(s) and/or
Faulty pressure protection
fittings are faulty.
valve.
Faulty main air supply hose.
Faulty CTIS manifold input
hose.
Faulty electrical system.
NO
Replace air hose(s) and/or
YES
fittings (para 23-2).