WARNING
Wear protective goggles to protect against
possible injury from release of high pressure
air. failure to comply may result in injury
to personnel.
NOTE
Inspect air hoses and fittings for cracks,
kinks, nicks, stripped threads, and cuts.
(1)
Loosen air hose at solenoid valve port P.
(2)
Check for presents of air at port P.
(3)
If air is not present, go to step 6 of this fault.
(4)
Tighten air hose on solenoid valve.
(1) Loosen air hose at solenoid valve port A.
(2) Check for presents of air at port A.
(3) If air is not present, replace solenoid valve
(para 32-10).
(4) Tighten air hose on solenoid valve.