Click here to make tpub.com your Home Page

Page Title: Table 2-49.10. Inversion Valve Control Port Fitting Hose Numbers
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home
   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-366-20-2
(1) Loosen air hose (refer to Table 2-49.10.
Inversion Valve Control Port Fitting Hose
Numbers) at inversion valve control port
90-degree fitting supply port.
(2) Start engine (TM 9-2320-366-10-1).
(3) Apply service brakes (TM 9-2320-366-10-1).
(4) Check for presence of air at air hose
(refer to Table 2-49.10. Inversion Valve
Control Port Fitting Hose Numbers).
(5) Shut down engine (TM 9-2320-366-10-1).
(6) If air is not present, replace air hose
(refer to Table 2-49.10. Inversion Valve
Control Port Fitting Hose Numbers)
(para 11-21).
(7) If air is present, replace inversion valve
control port 90-degree fitting (para 11-13).
(8) Tighten air hose (refer to Table 2-49.10.
Inversion Valve Control Port Fitting Hose
Numbers) at inversion valve control port
90-degree fitting supply port.
Table 2-49.10. Inversion Valve
Control Port Fitting Hose Numbers
Model
Hose
All Except M1086 and M1089
130
M1086
132
M1089
128
Change 1