TM 9-2320-366-20-2
TM
INITIAL SETUP
Equipment Conditions
Tools and Special Tools
Engine shut down (TM 9-2320-366-10-1).
Tool Kit, Genl Mech (Item 46, Appendix C)
Goggles, Industrial (Item 15, Appendix C)
START
KNOWN INFO
TEST OPTIONS
1.
Nothing.
Visual inspection
REASON FOR QUESTION
POSSIBLE PROBLEMS
Is dessicant cartridge
Dirty desiccant cartridge
Dessicant cartridge dirty.
clean?
will cause dryer not to
Faulty air dryer purge valve.
purge and will result
Blocked governor air hose.
in excess moisture in
Faulty air compressor.
system.
NO
Service air dryer
YES
(para 23-11).
KNOWN INFO
TEST OPTIONS
2.
Visual inspection
Desiccant cartridge OK.
POSSIBLE PROBLEMS
REASON FOR QUESTION
Is purge valve
A blocked purge valve
Faulty air dryer purge valve.
clear?
will cause dryer not to
Blocked governor air hose.
purge and will result
Faulty air compressor.
in excess moisture in
system.
NO
Service air dryer
YES
(para 23-11).
|