TM 9-2320-366-20-2
(1) Push in SYSTEM PARK air supply valve.
(2) Pull SYSTEM PARK air supply valve out
and note release of air.
(3) If air is not heard escaping from inversion
valve, replace inversion valve (para 11-13).
(1) Push in SYSTEM PARK air supply valve.
(2) Pull SYSTEM PARK air supply valve out
and note release of air.
(3) If air is not heard escaping from anti-
compounding relay valve, replace anti-
compounding relay valve (para 11-12).
(4) If air is heard escaping from anti-
compounding relay valve, repair rear
brake plunger assembly(ies) (para 11-5).
(5) Pull SYSTEM PARK air supply valve out.
Change 1
|