TM 9-2320-366-20-2
(1) Tighten air hose 109 at two-way check valve
supply port.
(2) Loosen air hose (refer to Table 2-48.1. Air
Hose Numbers) at delivery port of two-way
check valve.
(3) Release SYSTEM PARK (TM 9-2320-366-10-1)
and check for presence of air at air hose (refer
to Table 2-48.1. Air Hose Numbers).
(4) If no air is present, replace two-way check
valve (para 11-16).
Air Hose Number
Model Used On
131
M1089
M1083/M1088/M1090/
133
M1094/M1092
136
M1086/M1096
138
M1085/M1084