TM 9-2320-366-20-2
RESISTANCE TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter
to connector P119. Refer to Table 2-25.
Transmission Solenoid F and G Resistance
Test Points.
(3)
Connect negative (-) probe of multimeter to
connector P119 and note reading on
multimeter. Refer to Table 2-25.
Transmission Solenoid F and G Resistance
Test Points.
(4)
Connect negative (-) probe of multimeter to
all other pins in connector P119, one at a
time, and note reading on multimeter.
(5)
Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(6)
If good resistance is not noted in step 3, or
continuity is present in step 4 or step 5,
transmission harness external wiring
harness may be faulty, notify DS
Maintenance.
(7)
If good resistance is noted in step 3, and
continuity is not present in step 4 or step 5,
replace WTEC II TEPSS (para 8-2).
(8)
Connect connector P119 to connector J119.
(9)
Position front grille on cab with washer and
screw.
(10)
Position two washers and screws in front
grille.
(11)
Tighten screw to 48-60 lb-in. (5-7 Nm).
(12)
Tighten two screws to 24 lb-in. (3 Nm).
(13)
Connect connectors J114 and J115 to
WTEC II TEPSS.
(14)
Install instrument panel assembly (para 7-15).
(15)
Clear diagnostic codes (para 8-4).
Resistance Test Points
Sub
Affected
Connector
Connector
Code
Solenoid
P119 High
P119 Low
21
F
F
H
26
N
K
A
Change 1
|