Click here to make tpub.com your Home Page

Page Title: RESISTANCE TEST
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home
   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-366-20-2
RESISTANCE TEST
(1) Disconnect connector P119 from connector
J119.
(2) Set multimeter to ohms.
(3) Connect positive (+) probe of multimeter
to connector P119. Refer to Table 2-21.
Connector P119 Transmission Solenoid
Resistance Test Points for appropriate sub
code(s) and connector P119 pin(s).
(4) Connect negative (-) probe of multimeter to
connector P119 and note reading on
multimeter. Refer to Table 2-21.
Connector P119 Transmission Solenoid
Resistance Test Points for appropriate
sub code(s) and connector P119 pin(s).
NOTE
Transmission solenoid resistance is
affected by temperature. Refer to Table
2-22. Transmission Solenoid Resistance
Readings.
(5) If resistance reading indicates transmission
solenoid is good, replace WTEC II TEPSS
(para 8-2).
(6) If resistance reading indicates transmission
solenoid is faulty, notify DS Maintenance.
(7) Connect connector P119 to connector J119.
(8) Position front grille on cab with washer and
screw.
(9) Position two washers and screws in front
grille.
(10) Tighten screw to 48-60 lb-in. (5-7 Nm).
(11) Tighten two screws to 24 lb-in. (3 Nm).
(12) Clear diagnostic codes (para 8-4).
Table 2-21. Connector P119 Transmission Solenoid
Resistance Test Points
Table 2-22. Transmission Solenoid Resistance
Connector P119
Sub
Readings
Code
Positive (+) Probe
Negative (-) Probe
12
P119M
P119B
Temperature
Resistance
13
P119T
P119N
14
P119C
P119V
4 to 16F (-20 to -10C)
2.50-3.12
ohms
15
P119W
P119B
16 to 32F (-10 to 0C)
2.62-3.25
ohms
16
P119U
P119N
32 to 50F (0 to 10C)
2.74-3.38
ohms
21
P119F
P119H
50 to 68F (10 to 20C)
2.86-3.50
ohms
22
P119D
P119V
68 to 86F (20 to 30C)
2.98-3.62
ohms
23
P119P
P119S
86 to 104F (30 to 40C)
3.09-3.75
ohms
24
P119J
P119B
104 to 122F (40 to 50C)
3.21-3.88
ohms
26
P119K
P119A
122 to 140F (50 to 60C)
3.33-4.00
ohms