Page Title: RESISTANCE TEST
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home
   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-366-20-2
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back and
are capable of making good contact.
RESISTANCE TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter on
P119a.
NOTE
Transmission sump oil temperature sensor
resistance reading is affected by temperature.
Refer to Table 2-19. Transmission Sump
Oil Temperature Sensor Resistance Readings
for details.
(3) Connect negative (-) prove of multimeter on
P119d and note reading on multimeter.
(4) Connect negative (-) probe of multimeter to
all other pins in connector P119, one at a
time, and note reading on multimeter.
(5) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(6) Connect positive (+) probe of multimeter to
connector P119d.
(7) Connect negative (-) probe of multimeter to
all other pins in connector P119 (except
(P119a), one at a time, and note reading on
multimeter.
(8) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(9) If correct resistance is not present in step 3,
or continuity is present in step 4, 5, 7, or 8,
notify DS Maintenance.
(10) If correct resistance is present in step 3 and
continuity is not present in step 4, 5, 7, or 8,
replace WTEC II TEPSS (para 8-2).
Table 2-19. Transmission Sump Oil Temperature
(11) Connect connector P119 to connector
Sensor Resistance Readings
J119.
(12) Position front grille on cab with washer and
Temperature
Resistance
screw.
(13) Position two washers and screws in front
-4 to 14F (-20 to -10C)
691-754 ohms
grille.
14 to 32F (-10 to 0C)
754-820 ohms
(14) Tighten screw to 48-60 lb-in. (5-7 Nm).
32 to 50F (0 to 10C)
820-889 ohms
(15) Tighten two screws to 24 lb-in. (3 Nm).
50 to 68F (10 to 20C)
889-962 ohms
(16) Clear diagnostic codes (para 8-4).
68 to 86F (20 to 30C)
962-1039 ohms
86 to 104F (30 to 40C)
1039-1118 ohms
104 to 122F (40 to 50C)
1118-1202 ohms
122 to 140F (50 to 60C)
1202-1286 ohms