e151. M1088/M1089 WORKLIGHTS DO NOT ILLUMINATE IN BLACKOUT MODE WITH
BLACKOUT OVERRIDE SWITCH ON
INITIAL SETUP
Equipment Condition
Tools and Special Tools
Engine shut down (TM 9-2320-366-10-1).
Tool Kit, Genl Mech (Item 46, Appendix C)
STE/ICE-R (Item 41, Appendix C)
Personnel Required
Multimeter, Digital (Item 22, Appendix C)
(2)
Wrench, Torque, 0-200 lb-in. (Item 59, Appendix C)
References
Materials/Parts
TM 9-4910-571-12&P
Wire, Elect, 50 ft (Item 71, Appendix D)
START
WARNING
KNOWN INFO
TEST OPTIONS
Read WARNING
1.
Circuit breaker OK.
Voltage Test or
on following page.
Worklights normal
STE/ICE-R #89
Is 12 vdc present at
REASON FOR QUESTION
mode OK.
connector P906-5?
POSSIBLE PROBLEMS
This question eliminates
Faulty blackout override
possible problems and
switch.
determines where
Faulty dashboard cable
troubleshooting continues.
NO
assembly.
Faulty auxiliary panel cable
assembly.
YES
Go to step 3 of this fault.
Faulty relay K12.