e144. M1090/M1094 DUMP BODY DOES NOT LOWER (CONT)
CAUTION
Read CAUTION
KNOWN INFO
TEST OPTIONS
on following page.
10.
Continuity Test or
Hydraulic oil level OK.
STE/ICE-R Test #91
PTO OK.
Is continuity present from
REASON FOR QUESTION
Circuit breaker CB50 OK.
connector P909 socket 5 to
If continuity is not present,
connector J912 socket 1?
POSSIBLE PROBLEMS
wire 2006 in auxiliary panel
cable assembly is faulty. If
Faulty auxiliary panel cable
continuity is present, wire
assembly.
2006 in dashboard cable
Faulty dashboard cable
assembly is faulty.
assembly.
NO
Repair wire 2006 from connector
P909 socket 5 to connector J912
YES
socket 1 (para 2-45) or replace
auxiliary panel cable assembly
(para 7-58).
Repair wire 2006 from connector
P912 pin 1 to circuit breaker CB50
(para 2-45) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).