Click here to make tpub.com your Home Page

Page Title: M1090/M1094 DUMP BODY DOES NOT LOWER
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home
   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-366-20-2
e144. M1090/M1094 DUMP BODY DOES NOT LOWER
INITIAL SETUP
Equipment Condition
Tools and Special Tools
Engine shut down (TM 9-2320-366-10-1).
Tool Kit, Genl Mech (Item 46, Appendix C)
STE/ICE-R (Item 41, Appendix C)
Personnel Required
Multimeter, Digital (Item 22, Appendix C)
(2)
Goggles, Industrial (Item 15, Appendix C)
Sling, Cargo (Item 31, Appendix C)
References
Lifting Bracket, Dump Body (2) (Item E-24, Appendix E)
TM 9-4910-571-12&P
Wrench, Torque, 0-200 lb-in. (Item 59, Appendix C)
Socket Set, Socket Wrench (Item 34, Appendix C)
Materials/Parts
Wire, Elec, 50 ft (Item 71, Appendix D)
NOTE
Perform Electrical System Troubleshooting
e1. Circuit Breaker Does Not Operate on
circuit breaker CB50 prior to beginning
this task.
START
WARNING
CAUTION
Read WARNING and
CAUTION on
KNOWN INFO
TEST OPTIONS
following page.
1.
Voltage Test or
Hydraulic oil level OK.
STE/ICE-R Test #89
PTO OK.
Is 24 VDC present at
REASON FOR QUESTION
Circuit breaker CB50 OK.
connector L9 socket 1?
This question eliminates
POSSIBLE PROBLEMS
possible problems and
determines where
Faulty dump body hydraulic
troubleshooting continues.
system.
Faulty solenoid valve.
Faulty DUMP BED UP/DOWN
switch.
NO
Faulty auxiliary panel cable
assembly.
Faulty M1090/M1094 dump
cable assembly.
Faulty M1090/M1094 dump
YES
Go to step 5 of this fault.
power cable assembly.
Faulty dashboard cable
assembly.
Change 2

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business