TM 9-2320-366-20-2
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back and
are capable of making good contact.
CONTINUITY TEST
(1) Disconnect batteries (para 7-57).
(2) Remove kick panel (para 16-3).
(3) Disconnect connector P108 from connector
J108.
(4) Set multimeter to ohms.
(5) Connect positive (+) probe of multimeter
to connector J108 pin 6.
(6) Connect negative (-) probe of multimeter
to connector P911 socket 7 and note
reading on multimeter.
(7) If continuity is not present, repair wire
2043 from connector J108 pin 6 to
connector P911 socket 7 (para 2-45) or
replace auxiliary panel cable assembly
(para 7-58).
(8) Connect connector P911 to DUMP BED
UP/DOWN switch.
(9) Position auxiliary panel on auxiliary
panel housing with six screws.
(10) Tighten six screws to 24 lb-in. (3N.m).
Change 1
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |